Emergency UGA tree server updates
Servers in the UGA tree need to have emergency patches applied ASAP. This work needs to be
completed by the close of business on Friday March 7, 2003. Please let us know if you will be able to
complete these updates by Friday. If you need assistance in completing the required updates in time
please contact us through the EITS Helpdesk at (706) 542-3106. Thank you very much for
your assistance in these updates.
The following table lists appropriate patches and the patch order, depending on the Directory Services
level that the server is running. The patches can be found from:
- the EITS Novell Patches web
page.
- the SITESOFT server. The DATA volume, Novell directory contains all updates and ISO images
containing these updates. Everyone should have Read and File Scan rights to this directory.
For common questions regarding these updates, please look here.
| DS Version | Patches Necessary |
| 10350.16 | None |
| 10350.13 | edir 8.6.2 sp3b |
| 10350.12 | edir 8.6.2 sp3b |
| 10350.07 | edir 8.6.2 sp3b |
| 10320.29 | edir 8.6.2 sp3b |
| 10320.04 | nw6sp2, edir 8.6.2 sp3b |
| 10310.17 | nw6sp2, edir 8.6.2 sp3b |
| 8.82 | edir8.6.2, edir 8.6.2 sp3b |
| 8.79 | nw5sp5, jvm 1.31, edir8.6.2, edir 8.6.2 sp3b |
| 8.77 | nw5sp5, jvm 1.31,edir8.6.2, edir 8.6.2 sp3b |
| 8.59 | nw5sp5, jvm 1.31, edir8.6.2, edir 8.6.2 sp3b |
| 8.38 | nw5sp5, jvm 1.31, edir8.6.2, edir 8.6.2 sp3b |
| 85.23 | edir8.6.2, edir 8.6.2 sp3b |
| 85.20 | nw5sp5, jvm 1.31, edir8.6.2, edir 8.6.2 sp3b |
| 6.16 | Contact the EITS Helpdesk to discuss upgrade
possibilities |
| 6.09 | Contact the EITS Helpdesk to discuss
upgrade possibilities |
If you don't know the DS verion running on your server check the following table.
| Server Name | DS Version | Server Name | DS
Version |
| ADA | 10320.29 | MATH_MAIN | 85.20 |
| ADV_LAB | 10310.17 | MCWHORTER | 6.09 |
| AGECON | 10320.04 | MEMORIAL | 10320.29 |
| ALISON | 10310.17 | MSD | 10350.16 |
| AUDIT | 10350.16 | NOVA | 10350.12 |
| BIGBOY | 10350.12 | OASP_FS | 10320.04 |
| BUGS | 10320.29 | OPHELIA | 10350.12 |
| CAMELOT | 8.79 | PARK_LAB | 8.38 |
| CENTURY | 10350.12 | PARK-GRAD | 8.82 |
| CLC_SRVR | 85.23 | PORTAL1 | 10350.16 |
| COE_LABS_NEW | 10320.04 | PORTAL2 | 10350.16 |
| COE_LABS_RV | 10310.17 | RECSPORTS | 10320.04 |
| COE_OFFICE | 10320.04 | SITESOFT | 10350.16 |
| COE_OFFICE_RV | 10320.29 | SOPHIA | 6.16 |
| COE_OFFICE_RY | 10320.29 | STATLAB | 10350.07 |
| COMMUNITY1 | 10350.16 | STDC_STAFF | 10320.04 |
| COMMUNITY2 | 10350.16 | STDC_TRAIN | 85.23 |
| COMPLIT | 10320.04 | STUACT1 | 10320.29 |
| EDS1 | 10350.16 | TAB | 85.30 |
| EDS2 | 10360.16 | UCNS_AH | 10320.29 |
| EDS3 | 10350.16 | UCNS_BH | 10320.29 |
| EOO_FS | 10350.13 | UCNS_CH | 8.82 |
| GSLANGS | 10320.04 | UCNS_CSA | 10350.07 |
| HESTIA | 10350.07 | UCNS_FH | 8.82 |
| HONORS_SERVER | 10350.12 | UCNS_JB | 10320.29 |
| HOUSING | 10320.29 | UCNS_MEM | 85.23 |
| HOUSING_FAMILY | 8.82 | UCNS_ML | 8.82 |
| HR | 8.79 | UCNS_MR | 8.79 |
| ICJE | 8.59 | UCNS_OH | 8.82 |
| INTED | 10320.04 | UCNS_RH | 8.82 |
| ISD_OFFICE | 10350.07 | UGA1 | 10350.16 |
| JW | 10350.07 | UGA2 | 10350.16 |
| LASER | 10320.04 | VEEP | 10320.04 |
| LEGAL | 10350.16 | VPPSO | 8.77 |
| LUCY | 10350.07 | ZEN | 10350.16 |
Common questions during the update installations:
- JVM 1.31:
This is a windows based install. Simply run the self-extracting archive, then run SETUP.EXE. You will
have to have a drive mapped from windows to the server that you wish to install the JVM to. All other
patches are installed through NWCONFIG.
- eDir 862 install:
After running the initial install through NWCONFIG and rebooting, you are not done with the eDir 862
install. You will need to authenticate to finish the install. Next, you will be asked whether this is
a Local or Remote install. If you are installing remotely, I.E. not physically at the machine, choose
REMOTE INSTALL. Otherwise, the installer will launch a graphical install wizard through XWindows and it
will wait for user interaction before finishing the install.
- 8.6.2SP3B:
Upgrading from eDirectory 8.6.2 SP3 (v. 10350.12) to 8.6.2 SP3B (v. 10350.16) the installer will ask you
if you want to ONLY COPY REMAINING FILES or COPY ALL FILES ALL OVER AGAIN or something to that effect.
You have to choose COPY ALL FILES OVER. The two patches are close enough together that NWCONFIG things
that the SP3B patch install is just your attempt to reinstall SP3 again.
Contact EITS if you have any questions about these updates.
|